Sign In | Join Free | My ecer.co.uk
China PEAK Instruments (Shanghai) Co., Ltd. logo
PEAK Instruments (Shanghai) Co., Ltd.
PEAK Instruments (Shanghai) Co., Ltd.
Verified Supplier

1 Years

Home > UV Visible Spectrophotometer >

T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm

PEAK Instruments (Shanghai) Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm

Warranty : 1 year

Customized support : OEM, ODM

Place of Origin : Shanghai, China

Brand Name : PEAK INSTRUMENTS

Model Number : T-9200

Size : 61*46*24CM

Weight : 23KG

Focal Length : Null

Wavelength Range : 190-1100nm

Display : 7 inch capacitive touch screen

Optical System : Double beam, Holographic Grating (1200 Lines/mm)

Spectral Bandwidth : 2nm

Wavelength Accuracy : ±0.3nm

Wavelength Repeatability : ≤0.2nm

Stray light : ≤0.05%T@220, 360nm

Baseline Flatness : ±0.002A

Noise : 0.0003@500nm

Detector : Solid Silicon Photodiode

Light Source : Deuterium/Tungsten Lamp

Packaging Details : Carton Box

Price : $2,495.00/units 1-9 units

MOQ : 1 unit

Contact Now

Product Description
Product Name
7 inch touch screen double beam 190-1100nm UV Visible 2 nm spectrophotometer
Origin
China
Brand
PEAK INSTRUMENTS
Model
T-9200
Size
61*46*24CM
Weight
23KG
Wavelength range
190-1100nm
Display
7 inch touch screen
Optical System
Double beam, Holographic Grating (1200 Lines/mm)
Spectral Bandwidth
2 nm
Wavelength Accuracy
±0.5nm
Wavelength Repeatability
≤0.2nm
Stray Light
≤0.05%T@220, 360nm
Baseline Flatness
±0.002A
Noise
0.0003@500nm
Detector
Solid Silicon Photodiode
Light Source
Deuterium & Tungsten Lamp
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
1. Photometry Measurements
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
2. Quantitative Test
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
3. Kinetics Measurement(time scanning)
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
4. Wavelength Scanning
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
5. Multiwavelength Test
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
6. DNA/Protein measurement
Our Advantages
Quality
1. Our products have good quality and very positive reputations in the market.
2. Customers are very happy with them and have a lot of good comments about our intruments and service.
Delivery Time
1. We can get them ready 3-5 days after order confirmation for small orders.
2. For big quantities, need to be confirmed.
3. In most cases, fast delivery is guaranteed.
Technical Support
1. We have service manual. If not, detailed documents or videos will be provided.
2. We can provide online or site training in our factory.
3. We can have video conference at any time.
Aftersales Support
1. Respond to your questions within 10 minutes during our working time from 6:30 to 24:00, at most within 8 hours after 24:00 considering the time difference.
2. Within warranty, we will solve the problem for you with no charge(except for consumables).
3. You can call, text or email us at any time. We have good English speakers.
Warranty Time
One year and extendable
Our product advantages are as follws:
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
1. 7 inch capacitive touch screen and user friendly interface
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
2. Silicone buttons with much longer life span and easier to be operated
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
3. 7 inch color LCD screen(button models) can show more parameters
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
4. Standard USB ports for data transfer and PC software connection.
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
5. More functions for basic models
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
6. Stable system with microcomputer processing
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
7. Automatic 8 position 1 cm cell holder(optional)
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
8. Long path cell holder can holde 1-10cm cuvettes(optional)
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
9. Tube rack for tubes with 16mm diameters(optional for all models)
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
10. Film cell holder(optional for all models)
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
11. Automatic sampler/sipper system(optional)
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
12. PC software, thermal printer, etc.
Why Choose Us
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
1. Positive comments from our Italian client
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
2. Good review from our customer in Italy
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
3. Great comments from Syria client
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
4. UAE customer is satified with our pH meter
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
5. Argentina customer is happy with our pH meters
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
6. Turkey user is satisfied with its performance of spectrophotometer
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
7. Spain customer is very happy with our fast service and professional technical support
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
8. Indian client is happy with our great support
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
9. Peru customer likes our spectrophotometer very much
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
10. Salvador customer has good comments on our pH meter
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
11. South Africa customer is happy with the accuracy of our spectrophotometer and pH meter
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
12. Customer in Poland said our products are very good
Certifications
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm

CE

ISO 9001 and ISO14001 are also available
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm

CE ANNEX

Product process
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
1.Install main board
2.Connect the cables for main board
3.Install W1 lamp and D2 lamp
4.Assemble sample chamber and cell holder
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
5.Install power board
6.Assemble monochromator
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
7.Upload software
8.Adjust and test W1 lamp and D2 lamp
9.System test
10.Housing installation and final calibration
Customer Photos
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
Customer visit and training
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
Visit cutomers and have a training
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
Customer from Brazil
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
Visit and train customers in Chile
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
Training
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
Customer from Argentina
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
Clients from Korea
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
Distributor from Thailand
FAQ
Q: What areas and applications can it be used?
A: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.
Q: Does it need any installation
A: The installation is very simple, just need to connect it to power supply and turn it on, then you can use it.
Q: What standard accessories are included?
A: Main unit, 1cm cell holder(4 positions for single beam and 2 positions for double beam), 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1 cm quartz cuvette(UV models), one USB with user manual and power cable.
Q: Is PC software included?
A: The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.
Q: Why the reading is red and reach its maximum value 3.00Abs?
A: Probably you use the glass cuvette in UV range.
Q: Why the wavelength calibration or self checking fail?
A: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.
Q: Why is the reading is not as accurate as before?
A: Do the wavelength calibration before testing or restore the device to its default factory settings.
Q: Why PC software can not be installed successfully?
A: Close your anti-virus software on the computer and do it again.
Q: Why the software can not be connected successfully?
A: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.
Q: Can the data transferred to USB or PC?
A: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.
Q: Why the Abs value is negative(lower than zero).
A: Do the blanking or change the reference sample.
Exhibition
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
Analytica in Germany
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
Pittcon in USA
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
ArabLab in Dubai
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
IndiaLabExpo in India
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
Analytica Lab Africa
T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm
Analitica Latin America in Sao Paulo, Brazil

Quality T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm for sale

T-9200 2nm Touch Screen UV Visible Spectrophotometer with Wavelength Accuracy ±0.3nm Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: PEAK Instruments (Shanghai) Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)